Zendure Manager
The Zendure Manager tries to regulate the P1/house consumption sensor towards 0 W via the Zendure devices. To do this, it controls the charging and discharging performance of the devices.
HEMS and app programs
If Zendure Manager and HEMS or a power program in the Zendure app are controlling at the same time, they can work against each other. Only use an active control strategy.
P1 sensor
The P1 sensor should provide home consumption:
- positive value: house consumes mains electricity
- negative value: house feeds in
This sensor is the basis for Smart Matching.
Operating modes
| Mode | Meaning |
|---|---|
Aus | Manager does not control devices |
Manuelle Leistungsregelung | fixed power value via Manuelle Leistung |
Smarte Leistungsregelung | tries to keep the P1 sensor at 0W |
Smartes nur Entladen | like Smart Matching, but without loading |
Smartes nur Laden | only charges, does not discharge |
Solar speichern | stores solar/offgrid input preferably in batteries |
Manual performance
For Manuelle Leistungsregelung, the entity Manuelle Leistung determines how much power should be fed in or out.
- positive value: battery discharges towards house/grid
- negative value: Battery charges if the device supports AC charging
Smart matching
With Smart Matching, the manager distributes power to the available devices. Fuse group, charge level, minimum SoC, maximum performance and device status all play a role.
The original wiki describes the distribution logic as partially outdated. Therefore, this page should be seen as a guide and checked against the current code if necessary.
Original wiki: