FuseGroup
The Fuse Group is a security and tax group. It describes which Zendure devices are connected to the same fuse or circuit and what maximum power is permitted there.
responsibility
The correct selection of the Fuse Group is relevant to safety. Choose them to suit your electrical installation and local regulations.
Why it is important
Zendure Manager distributes power based on the fuse group setting. Devices in the same group together should not exceed the set limit.
Without a suitable fuse group, a device will not be used for smart functions.
Typical options
| option | Meaning |
|---|---|
Nicht verwendet | Device has no fuse group and is not used for smart matching |
Eigener Stromkreis / eigene Phase | Device depends on its own circuit |
Sicherungsgruppe max. 800 W | Group with a maximum of 800 W |
Sicherungsgruppe max. 1200 W | Group with a maximum of 1200 W |
Sicherungsgruppe max. 2000 W | Group with a maximum of 2000 W |
Sicherungsgruppe max. 2400 W | Group with a maximum of 2400 W |
Sicherungsgruppe max. 3600 W | Group with a maximum of 3600 W |
Sicherungsgruppe max. 4000 W | Group with a maximum of 4000 W |
Sicherungsgruppe max. 5000 W | Group with a maximum of 5000 W |
Connection status
The integration shows a connection status that helps with classification:
| Status | Meaning |
|---|---|
Unbekannt | no clear connection status |
Kalibrierung | Device calibrated |
HEMS | Device is affected by HEMS |
Keine Sicherungsgruppe | Fuse Group is missing |
Verbunden (Cloud) | Connection via cloud |
Verbunden (Local) | Connection via local MQTT |
Verbunden (zenSDK) | Connection via zenSDK |
Original wiki: